Skip to content

Troubleshooting

Symptoms, causes and fixes for the problems clients report most often.

Quick reference

Symptom Likely cause Go to
i-Con Client fails on start-up with "Root element is missing" Corrupt recent-projects file i-Con Client won't start
"Could not load file or assembly… manifest definition does not match" Missing or mismatched DLL Assembly errors
"Unable to upload interface to server" Service stopped, database unreachable or project locked Upload fails
"SSL Certificate add failed, Error: 1312" Certificate has no private key or is in the wrong store HTTPS binding fails
Interface can't start because the port is in use A previous process still holds the port Port already in use
Requests accepted but nothing is processed Service stopped or queue permissions wrong Queue backlog
SQL timeouts or connection failures Network, firewall, protocol or TLS settings Database connection
i-Con Client refuses to open for a user User isn't in an i-Con Active Directory group Access denied
Interface won't start: no initial component, or a source error InitialComponent not set, or no Source component Interface won't start
Uploaded changes have no effect The running interface wasn't restarted Interface won't start
Interface Manager shows no images or styling IIS Static Content isn't installed Interface Manager problems

For any problem with a running interface, start with Event Management → List Messages in the Interface Manager, filtered to Errors and System Error.

i-Con Client won't start

Symptom: An error dialog appears when the i-Con Client opens, mentioning Root element is missing or Object reference not set.

Cause: An unexpected shutdown or a full disk corrupted the file that stores recent projects.

  1. Close the i-Con Client.
  2. Go to C:\Program Files (x86)\Pro Solutions\i-Con Client\.
  3. Rename RecentProjects.xml to RecentProjects.xml.old.
  4. Check that Settings.xml and config.xml are intact.
  5. Start the i-Con Client. Your recent-projects list will be empty; reopen projects from disk.

Assembly load errors

Symptom: Could not load file or assembly… The located assembly's manifest definition does not match.

Cause: A third-party library is missing, or a different version is installed on the i-Con Client and the server.

  1. Confirm that libraries such as Newtonsoft.Json and System.Net.Http are present in both the i-Con Client and Server installation folders.
  2. Make sure the versions match, and that the binding redirects in Connector.exe.config refer to the installed versions.
  3. Restart the i-Con Client or the i-Con Service.

Upload to server fails

Symptom: Unable to upload interface to server.

  1. Check that I-Con service is running on the server.
  2. Check that the i-Con Client and server can reach the SQL Server hosting IConDb.
  3. Check that another user doesn't have the project locked.

HTTPS certificate binding fails

Symptom: An HTTPS interface won't start, with SSL Certificate add failed, Error: 1312.

Cause: The certificate has no private key, or it was imported into the wrong store (for example Web Hosting instead of Personal on the local computer).

  1. Open certlm.msc and confirm the certificate is under Personal and shows "You have a private key that corresponds to this certificate".
  2. Re-import it with its private key if needed, then bind it again (see Security).
  3. Give the service account read access to the private key.

Port already in use

Cause: A host process ended unexpectedly and still holds the port or its certificate binding.

  1. Find the process using the port:
Command
netstat -ano | findstr :<port>
  1. End that process in Task Manager (or with Microsoft's TCPView tool).

  2. If needed, remove the stale certificate binding and bind again:

Command
netsh http delete sslcert ipport=0.0.0.0:<port>

Messages back up in the queue

Symptom: Callers send transactions successfully but nothing happens downstream, and the heartbeat in the Interface Manager stops increasing.

  1. In services.msc, confirm I-Con service is running.
  2. In Task Manager, look for leftover ConServer.exe processes. If the service stopped abruptly, end them and restart the service.
  3. In Computer Management → Message Queuing → Private Queues → iconqueue, confirm the application pool identity and the service account have Full Control.

i-Con Client access denied

The i-Con Client checks Active Directory when it starts. Add the user to icondevuser or icondeveadmin (or the local Administrators group), then have them sign out and in again.

Interface won't start, or changes have no effect

  • No initial component selected: in the i-Con Client, set the project's InitialComponent and upload again.
  • Interface source error: the interface needs at least one component with EndPoint set to Source.
  • Old behaviour after an upload: stop and start the interface in the Interface Manager. A new version takes effect only after a restart.

Interface Manager problems

  • No images or styling: install the IIS Static Content role service.
  • Page won't load on 64-bit Windows: set Enable 32-Bit Applications on the application pool; if it still fails, switch the pool to Classic pipeline mode.
  • Access denied: add the user to the ICONWEB role.
  • Start or Stop does nothing: check that the application pool identity has Full Control on iconqueue and that the I-Con service is running.

Database timeouts or connection failures

  1. Confirm the server can reach the database host and port, and that no firewall blocks it.
  2. In SQL Server Configuration Manager, confirm TCP/IP and Named Pipes are enabled.
  3. Confirm TLS 1.2 and the cipher suites the database requires are enabled on the i-Con host.